How we calculate

Every number on this site comes from a formula in a published standard or from a standard size table. Nothing is copied from other charts; our results are tested against widely published tap drill pairs (for example 1/4-20 → #7, 10-32 → #21, M8 × 1.25 → 6.8 mm, 1/8 NPT → 11/32 in).

Thread geometry (UNC, UNF, ISO metric)

Percent of thread

% thread = (D − drill) ÷ (1.299038 × P) × 100. 1.299038 × P is the full thread depth used by US tap drill charts (twice ¾ of H). Inverted: drill = D − 0.01299 × %thread ÷ TPI.

Recommended tap drill

UNC and UNF

We compute the drill for 75% thread and pick the nearest standard number, letter or 1/64-inch fractional drill (on a tie, the smaller drill). The calculator on each page repeats this for 50–75% and for "fractional only" or metric drill sets.

Metric

Tap drill = D − P (ISO 2306 practice), on the steps metric drills are sold in: 0.05 mm below 3 mm, 0.1 mm up to 14 mm, 0.5 mm above. For four threads D − P lands exactly between two 0.1 mm drills; there we use the ISO 2306 size: M8 × 1.25 → 6.8, M12 × 1.75 → 10.2, M10 × 1.25 → 8.8, M12 × 1.25 → 10.8 mm.

NPT pipe threads (ASME B1.20.1)

From the pipe outside diameter D, threads per inch and the hand-tight engagement L1: E0 = D − (0.05 D + 1.1) × p, E1 = E0 + 0.0625 × L1, thread height h = 0.8 p. The tap drill (no reaming) is the largest 1/64-inch drill not larger than the minor diameter at the gauge plane, E1 − h. Pipe tap charts vary by up to 1/32 in above 1 inch; a taper pipe reamer lowers tapping torque.

Clearance holes

Metric: ISO 273 hole sizes (fine = close fit, medium = normal, coarse = loose). Inch: we add the ISO 273 allowance for the same diameter (interpolated between ISO 273 sizes) and take the smallest standard inch drill at least that size.

Drill sizes

Number (#1–#80) and letter (A–Z) drill diameters are the standard sizes of ASME B94.11M. Fractional drills are n/64 in. Conversions use exactly 25.4 mm per inch; we show inches to 4 decimals and millimetres to 2.

Lumber actual sizes

Nominal sizes such as 2x4 are converted to the minimum dressed (planed) sizes of the American Softwood Lumber Standard, NIST PS 20-25, Table 3: boards (under 2 in nominal), dimension lumber (2 to 4-1/2 in) and timbers (5 in and up), dry (moisture content 19% or less) and green (over 19%). Millimetres are inches × 25.4, shown to 0.1 mm as in the standard. Lengths and span tables are not covered.

Drawings and PDF charts

Drawings are generated from the numbers above in real millimetres. On screen their size depends on your display, so each has a scale bar. The PDF charts are US Letter and are exactly 1:1 when printed at 100% ("Actual size"); check with the printed 50 mm and 2 in rulers.

Limits

Charts give starting points. Tap makers sometimes recommend a different drill for forming taps, hard materials or specific tolerance classes — follow the tap maker's data when it differs. Found an error? Tell us.